Worcester Bosch Boiler Repairs(1)

Worcester Bosch Boiler Repair

Worcester Bosch Boiler Repair

Worcester Bosch Boiler specialist

Is your boiler damaged and in need of a repair? Why leave it that way when can get a Worcester Bosch boiler repair to fix it for you. Perhaps you just can’t cope with the high budget and time needed to get this done? We as a Worcester Bosch boiler repair agent, we understand your plights as well as your needs as an individual when it comes to repairing your boiler. That’s why we are offering this service at an unbeatable price, with enough flexibility to fit into your schedule.

We are not restricted to a particular type of model or make of boiler. Our experts have the required knowledge cut across several models and makes of boiler. Which means we can work on any Worcester bosh boiler you have installed in your home. Having the experience and knowledge in place, you need to look no further. As we are just a dial away from you.

Worcester Bosch boiler repair company

As a Worcester Bosch boiler repair company, we have the best in place. Here, our engineers are professionals groomed with the required training when it comes to handling natural gas. More so,  they are Gas Safe registered. Which means you can count on them with the handling of your highly sensitive boiler. We also have an insurance policy in place that protects you. With this, the safety of you and your home is guaranteed.

Even though natural gas is highly beneficial, they tend to cause havoc if not properly handled. With your boiler been damaged, you stand a great risk and this could cause severe damages to your home and environs if not the fixed right away. We have engineers that know how to repair a boiler without any gas leak. With our Worcester Bosch boiler repair, you can rest assured that you are safe because you have the best overseeing the repair of your boiler.

Moreover, winter is just around the corner looming. And of course, you need not be reminded of how cold winter can be here in London. Why go through this season without a properly functioning boiler when you can hire our Worcester Bosch boiler repair services and get it fixed.

Conclusion

Provided you reside here in the beautiful city of London, our services would reach you in a very timely manner. We are available 24/7, ready to give you the best when it comes to Worcester Bosch boiler repairs.

Get In Touch

You can contact Master Gas 24 hours a day and a member of our team will only be pleased to receive your call request.
By using Master Gas you can rest assured that your job will be completed by experts and to your satisfaction, not forgetting, of course, our workmanship guarantee. Call today
07948 009 319

 

Boiler Replacement London

Worcester Boiler Error Codes

Fault DescriptionSystem Behaviour
226Service tool has been connected in the blocking error history menu
FD 231The power has been interrupted during a lockout
C7 214Fan does not run during the start up phase – fan harness connector needs checking
C6 215Fan speed too high – check the fan harness and connector
C7 216Fan speed too low – check the fan harness and connector
C7 217Fan has stopped during appliance operation
C1 264Fan stopped during operation
C4 273Continuous fan operation for the last 24 hours – appliance temporarily blocked
E2 222Flow temperature sensor shorted
E2 233Flow temperature sensor disconnected
E9 276Primary flow temperature exceeded 95°c
E2 350Flow temperature sensor shorted
E2 351Flow temperature sensor disconnected
FA 306Ionisation detected after the gas valve closed
EA 227No ionisation detected after ignition
F7 228Isioniation current detected before burner start
EA 229Loss of ionisation signal during operation
EA 261Heat control module (HCM) potentially defective – reset the appliance
9U 233Control box or heat control module (HCM) is defective or loose, the HCM needs to be checked
C4 237Control box or heat control module (HCM) is defective
F0 238Gas valve or control box error – gas valve coils need checking
F0 239Control box or the heat control module (HCM) is defective – the control box connections need checking
F0 242Control box or the heat control module (HCM) is defective – the HCM and control box connections need to be checked
B7 257Control box or the heat control module HCM) is defective- the HCM and control box connections need to be checked
F0 258Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked
EH 258Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked
F1 259Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked
F0 262Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked
F1 263Control box or the heat control module (HCM) is defective – HCM or control box connections need to be checked
F0 272Control box or the heat control module (HCM) is defective – control box and connections need checking or HCM might not be inserted properly and need replacing
F0 280Control box or the heat control module (HCM) is defective – control box and connections need checking or HCM might not be inserted properly and need replacing
F0 290Control box is defective – HCM needs checking as it might not be inserted properly or need replacing
328Internal error with the mains voltage – frequency may be inconsistent
235Incompatible heat control module (HCM) software versions – control box needs latest software
356Low mains voltage – the voltage may be interrupted or inconsistent and needs checking
360Heat control module (HCM) invalid – the inserted HCM does not correspond with the control box
A8 362Low mains voltage – the voltage may be interrupted, inconsistent or heat control module (HCM) invalid
CC 800Outdoor sensor defect available when accessory outdoor sensor is connected
A1 281Pump stock or running dry
E9 224Flue or high limit thermostat activated
D4 341Primary flow temperature rising too fast
Fault DescriptionSystem Behaviour
208The boiler is in chimney sweep mode
200The boiler is in heating mode
201The boiler is in domestic hot water (DHW) mode
202The boiler is waiting – there was a heat demand from the on off or modulating control
203The boiler is on standby
204The boiler is waiting – the actual temperature is higher than the calculated or selected boiler temperature
212The temperature recorded by the flow temperature sensor or the safety sensor is rising too quickly
226Diagnosis tool was connected and is now locked out
260The flow temperature sensor is not detecting a rise in temperature following a burner start
265The boiler is waiting in response to a heat demand – the boiler regularly switches to partial load
268Component test phase
270The boiler is modulating upwards
283The boiler is preparing for a burner start – the fan and pump are activated
284The gas valve is switched
305The boiler is waiting for domestic hot water (DHW) operation to end
235The KIM (boiler identification module) is too new for the burner control unit
360The KIM that has been fitted is not compatible with the burner control unit
9A 361The burner control unit that has been fitted is not compatible with the KIM (boiler identification module)
9U 233The burner control unit or KIM (boiler identification module) is faulty
A3 317Short circuit in the flue gas temperature sensor contacts
B7 257The burner control unit or the KIM (boiler identification module) is faulty
C1 264No control signal or power supply to the fan during operation
C4 273The boiler was switched off for a maximum of 2 minutes because it had been operating continuously for more than 24 hours
C6 215The fan speed is too high
C6 216The fan speed is too low
C7 214The fan does not run during the start phase
C7 217The fan speed is irregular when starting up
CE 207Water pressure is too low
CE 266Pump test failed
D1 240The contacts of the boiler return temperature sensor have been short circuited
D1 241The contacts of the boiler return temperature sensor have been interrupted
D3 232The external switching contact has opened
D4 213The actual temperature recorded by the flow temperature sensor or return temperature sensor is rising too quickly
D4 271Actual temperature differential between flow and safety temperature sensor is too high
D4 286The boiler return temperature sensor has detected a return temperature higher than 105°c
E2 222Short circuit in the flow temperature sensor contacts
E2 223The flow temperature sensor contacts have been interrupted
E5 218The temperature captured by the flow temperature sensor exceeded 105°c
E9 210The temperature measured by the flue gas sensor is too high and is open
E9 219The safety temperature sensor has captured a temperature in excess of 105°C
E9 220The contacts for the safety temperature sensor have shorted or the safety temperature sensor has detected a temperature higher than 130°c
E9 224The contacts of the safety temperature sensor have been interrupted
E9 276The temperature flow sensor has measured a temperature in excess of 95°c
E9 277The safety temperature sensor has measured temperature in excess of 95°c
E9 285The boiler return temperature sensor has measured a temperature higher than 95°c
E9 318The flue gas temperature sensor contacts have been interrupted
EA 227An insufficient ionisation current was measured following ignition of the burner
EA 229The ionisation current detected by the system during the burning phase was insufficient
EA 234The contacts of the gas valve have been interrupted
EA 261The burner control unit is faulty
EA 269The ignition device has been activated for too long
F0 238The burner control unit KIM (boiler identification module) is faulty
F0 239The burner control unit KIM (boiler identification module) has an error. Cabling might have poor contact breaks and pinching or the plug and wiring of the burner control unit needs checking, also check the operating characteristics of the boiler by replacing the burner control unit.
F0 242, F0 243. F0 244. F0 245, F0 246. F0 247, F0 248, F0 249, F0 250, F0 251, F0 252, F0 253, F0 255, F0 259, F0 263, F0 267, F0 272The burner control unit (KIM) is faulty – the wiring of the burner control unit needs checking, also check the operating characteristics of the boiler by replacing the burner control unit.
F0 278The sensor test has failed – cabling and plug sensors need checking
F0 279The burner control unit, or KIM, is faulty – control unit may need replacing
F0 280The burner control unit is faulty
F0 287The burner control unit, or KIM, has an error
F0 290The burner control unit, or KIM, is faulty
F7 228An ionisation current was measured before the burner started
F7 328A brief power failure has occurred
FA 306An ionisation current was measured after the burner went out
FD 231The mains voltage was interrupted during an interlocking fault
EC 256The burner control unit has an error
EH 258The burner control unit is faulty – check the plug and wiring of the burner control unit.
H07The current water pressure is too low, limiting the performance in heat mode as well as domestic hot water (DHW) mode
HrEThe boiler keeps resetting
rEThe boiler resets
Fault DescriptionSystem Behaviour
Light offNo boiler demand
Light onHeating demand on boiler is OK
1 flash 5 seconds offNo ionisation detected after ignition
2 flashes 5 seconds offLoss of ionisation signal during operation
3 flashes 5 seconds offGas valve error
4 flashes 5 seconds offFirst safety timing error / ignition timing error
5 flashes 5 seconds offIonisation detected after burner stopped
Gas valve EV2 leak test failed
Gas valve EV1 leak test failed
Ionisation current detected before burner start
Gas valve error
Ionisation sensor shorted
4 flashes 5 second gap 1 long flashSensor test failed
4 flashes, 5 second gap, 2 long flashesSafety temperature too high
4 flashes, 5 second gap, 3 long flashesMax safety thermostat activated
4 flashes, 5 second gap, 4 long flashesReturn temperature too high
4 flashes, 5 second gap, 5 long flashesFlow temperature too high – supply sensor exceeded 110°c
1 long flash, 4 quick flashes, 5 second gap, 1 long flash, 4 quick flashesHeating control module (HCM) defective
2 long flashes, 4 quick flashes, 5 second gap, 2 long flashes, 4 quick flashesFan running too fast
Fan running too slow
No airflow after defined period of time
Fan not running
3 long flashes, 4 quick flashes, 5 second gap, 3 long flashes, 4 quick flashesMains voltage interrupted after locking error
4 long flashes, 4 quick flashes, 5 second gap, 4 long flash, 4 quick flashesInternal control board faults
5 long flashes, 4 quick flashes, 5 second gap, 5 long flash, 4 quick flashesAll other miscellaneous faults – reset the boiler by turning the control knob anti-clockwise to the reset position
Fault DescriptionSystem Behaviour
No lightNo power at control board
Light onAppliance on but not operating during demand
Slow flash ( mostly off flashes on)Ignition lockout
Slow flash ( mostly on flashes off)Flue overheat or heat exchanger overheat
Fast flashVolatile lockout sensor fan or code plug
2 pulsesCheck service mode switch is in minimum position
5 pulsesCheck service mode switch is in max position
Fault DescriptionSystem Behaviour
200 OBoiler in heating mode
201 OBoiler in hot water mode
202 OBoiler in anti-cycle mode
203 0Boiler in standby – no heat energy demand
204 OCurrent primary water temperature higher than set value
208 0Chimney sweep demand
224 VSafety temperature limiter has tripped – top-up water until the reset pressure is reached
227 VNo flame signal after ignition burner control unit could need replacing
228 VFlame signal without flame present – air/gas ratio control valve may need replacing as might the ionisation cable
305 0Boiler in hot water anti-cycle mode
306 VFlame signal after closing the fuel supply – the air/gas ratio control valve might need replacing
360 VIncompatible code plug – check if a correct code plug is installed and exchange or reconnect code plug
815 W/BLow loss header temperature sensor faulty – check the sensor port or check the differential sensor for incorrect installation position or breakage
1010 ONo BUS communication cable, EMS-Bus isn’t connected or damaged – connect the cable for the EMS-Bus or replace the damaged cable exchange fuse
1017 WWater pressure too low – the water needs topping up and the vent system or pressure sensor may need replacing
1021 BHot water temperature sensor is defective – the plug to the hot water temperature sensor may not be connected
1022 BHot water storage temperature sensor is defective – connect the plug to the hot water temperature sensor correctly, mount the hot water temperature sensor correctly or replace the hot water temperature sensor
1037 WOutside temperature sensor is defective – check the connecting lead
1065 BPressure sensor defective or not connected – check pressure sensor connection as it may need replacing
1068 WOutside temperature sensor defective – check the connecting lead
1073 WShort circuit of the flow temperature sensor – the temperature sensor may need replacing
1074 WNo signal from the flow temperature sensor available – connect the plug to the flow temperature sensor correctly or temperature sensor could need replacing
1075 WShort circuit of the temperature sensor at the heating block – temperature sensor may need replacing
1076 WNo signal from the temperature sensor at the heating block available – replace the temperature sensor, the connecting lead or the control unit
2920 VError with the flame monitoring
2924 VNo feedback from the modulating gas valve. The gas valve relay is defective – press the reset button and apply burner start, wait to see if fault reoccurs, if it does the gas valve needs replacing
2925 VFeedback from the modulating gas valve is too low
2927 BFlame failed during burner operation. Open the main shut off valve, shut down the appliance and check gas line, replace the ionisation electrode, set burner correctly and minimum rated load, check the integrity flue system and if the interconnected room air supply is too small, or the size of the ventilation opening is too small, clean the heating block on the flue gas side or replace the control unit/burner control unit
2946 VIncorrect code plug detected – the code plug needs replacing
2948 BNo flame signal. With low output the burner starts automatically after cleaning. If the fault occurs repeatedly, the setting of the CO2 valves need checking
2950 BNo flame signal. Following starting procedure the burner starts automatically. After cleaning set the correct gas / air ratio correctly
2963 BSignal from flow and heat exchanger temperature sensor outside the permissible range – the connecting lead needs connecting correctly
2964 BFlow rate in heat exchanger is too low
2965 BFlow temperature too high
2966 BFlow temperature rise in heat exchanger too rapid
2967 BFlow / heat exchanger temperature sensor differential too great
2970 BPressure drop in heating system too rapid
2971 BSystem pressure too low – the heating system needs venting or water needs topping up until the preset pressure is reached. Replace the cable to the pressure sensor replace the pressure sensor