Master gas london are your trusted partner in all things gas, heating and hot water

Vaillant F10 Fault Code

Vaillant F10 Fault Code

vaillant f10 fault code, what it means and how to fix it

Vaillant F10 Fault Code – What It Means & How to Fix It

Seeing the Vaillant F10 fault code usually points to a flow temperature sensor (flow NTC) short-circuit or a shorted wiring/connector on that circuit. When the boiler can’t trust the outgoing water temperature reading, it locks out for safety.

 

This guide explains what Vaillant F10 means, common causes, safe homeowner checks, how an engineer will fix it, typical UK costs, and how to stop it returning.

What Does the Vaillant F10 Fault Code Mean

In plain English: the boiler believes the flow temperature sensor is reading short-circuit / too low resistance (sometimes described as “short to earth”). Without a valid flow temperature, the boiler won’t fire or will immediately lock out. This is the flow (outgoing) pipe sensor, not the return sensor.

new boiler installation from £1900

New Boiler Installation

A-rated boilers installed from £1795

Common Causes of the Vaillant F10 Fault Code

Likely Cause What’s Happening Recommended Action
Failed flow NTC (short-circuit) Sensor resistance has dropped to an out-of-range “short” value Gas Safe engineer to test/replace the flow NTC
Damaged/shorted wiring or plug Pinched cable, rubbed insulation, or bridged pins causing a short Repair/replace loom; re-seat and secure connectors
Moisture/corrosion at terminals Water ingress leads to tracking and false short readings Dry/clean terminals; fix the source of leaks or condensation
PCB input fault Control board misreads the sensor even when it’s healthy Engineer to verify PCB input; replace if out of spec

Safe checks a homeowner can do (no tools, no casing)

  • System pressure: With the system cold, aim for ~1.0–1.5 bar (per your manual).

 

  • Look for leaks: Any damp below/around the boiler or pipework should be reported quickly.

 

  • One reset only: After external checks, try one reset from the user controls. If the Vaillant F10 fault code returns, stop and call a Gas Safe engineer.

 

Do not remove the boiler casing or probe wiring – internal work is Gas Safe only.

How an engineer fixes F10 (typical workflow)

Engineer Step Detail Outcome
Confirm sensor fault Measure flow NTC resistance vs. temperature; compare to spec sheet Confirms sensor state (OK/shorted) and rules out false flags
Check loom & connectors Continuity and insulation checks; inspect for shorts, pinches, corrosion Restores a clean, stable signal path
Moisture/leak rectification Identify/stop water ingress; dry, clean and protect terminals Prevents repeat “short” readings
PCB verification Verify PCB input range and live readings under load Determines if board replacement is required
Functional run test Reassemble, reset, call for heat; verify stable modulation and temps Proves the fault is fully cleared
fixed price boiler installation from £1800, instant online boiler installation quote in under 60 seconds

Boiler Cover Plans

Get complete boiler cover from £12p/m

vaillant 10 year warranty

Typical repair costs (UK guide)

Repair Item Indicative Cost (UK)
Diagnostic visit (Gas Safe) £70 – £120
Flow NTC sensor replacement £90 – £150
Wiring/connector repair £100 – £180
PCB replacement (if required) £250 – £450

Prices vary by model, parts, access and region. We confirm costs up-front.

Symptoms you might see with F10

  • Immediate re-lock after a reset (sensor still reading short)

 

  • Erratic temperature behaviour followed by lock-out

 

  • A history of leaks/condensation near the boiler or within the case

 

  • Event log entries showing sensor/NTC faults alongside other Vaillant boiler fault codes

worcester bosch 2000 combi

Boiler Repairs

Boiler not working? We’ll fix it from £108

Repair or replace?

If the appliance is otherwise healthy, replacing the flow NTC or repairing a shorted loom is a quick, low-cost fix. If the boiler is older and you’re also seeing board failures, pump issues or repeated sensor faults, it may be worth pricing a new boiler installation with modern controls and a long warranty.

Repair or replace?

If the appliance is otherwise healthy, replacing the flow NTC or repairing a shorted loom is a quick, low-cost fix. If the boiler is older and you’re also seeing board failures, pump issues or repeated sensor faults, it may be worth pricing a new boiler installation with modern controls and a long warranty.

How to Avoid F10 and Other Sensor Faults

To reduce the chance of the error returning:

These steps help maintain accurate temperature control and prolong boiler lifespan.

FAQs: Vaillant F10 Fault Code

What does Vaillant F10 mean?
A flow temperature sensor (flow NTC) short-circuit or a related wiring/PCB issue that causes the boiler to lock out.

 

Can I fix Vaillant F10 myself?
No. You can check pressure, look for visible leaks and try one reset – internal diagnostics are Gas Safe only.

 

Will a reset clear it?
A reset might clear a one-off glitch, but a true flow NTC short will typically re-appear until repaired.

 

Is it dangerous?
The lock-out is a safety response. Don’t bypass it; book a qualified engineer.

 

How do I stop it returning?
Fix any moisture sources, ensure sound wiring, and keep up with annual servicing.

Related Vaillant Fault Codes

Relevant Services

Relevant Articles

Popular Services

fixed price boiler installation from £1800, instant online boiler installation quote in under 60 seconds

Boiler Cover Plans

Get complete boiler cover from £12p/m

new boiler installation from £1900

New Boiler Installation

A-rated boilers installed from £1795

Glow Worm boiler installation from £2015

Boiler Service

Book your boiler service for just £108

worcester bosch 2000 combi

Boiler Repairs

Boiler not working? We’ll fix it from £108

Indirect unvented cylinder prices all include installation

Unvented Cylinder Installation

Premium cylinders installed from £1599

grant aerona 3 air source heat pump installation

Air Source Heat Pumps

Free survey & quote for all ASHP installs